CAT5 Solid U/UTP Outdoor Ethernet Cable Custom Lengths Made to Order

£2.79£99.79

Out of stock

CAT5 Solid U/UTP Outdoor Ethernet Cable Custom Lengths Made to Order

SKU: CAT-5-EXT-CUSTOM- Categories: ,

Description

CAT5 Solid U/UTP Outdoor Ethernet Cable Custom Lengths Made to Order

CAT5e Solid U/UTP Outdoor Ethernet Cable is manufactured and tested to the ISO 11801, EN 50173 and ANSI/TIA-568-C standards for enhanced performance Category 5 cables. The cable consists of 8 colour coded polyethylene insulated conductors, twisted together to form 4 pairs with varying lay lengths. These pairs are jacketed in a heat and UV, moisture resistant black polyethylene outer sheath, making this cable ideal for outdoor installation. The print legend on the cable includes information regarding the DOP number, Test and Classification of the cable for traceability.

Key Features

  • Category: 5E
  • Length: Custom Lengths Made to Order
  • Outer sheath colour: Black
  • Supports Gigabit Ethernet
  • Sequential metre markings
  • Reaction-to-fire class according to EN 13501-6: Fca
  • AWG-size: 24
  • Euroclass Fca

Additional information

Dimensions N/A
Length

0.2M, 0.5M, 1M, 2M, 3M, 4M, 5M, 10M, 15M, 20M, 25M, 30M, 35M, 40M, 45M, 50M, 60M, 70M, 80M, 90M, 100M

Tech Specs

Category

  • 5E

Overall screening

  • None

Conductor screening

  • None

Outer sheath colour

  • Black

Reaction-to-fire class according to EN 13501-6

  • Fca

AWG-size

  • 24

Specification core insulation

  • PE

Core identification

  • Colour

Outer sheath material

  • PE

Halogen free (acc. EN 60754-1/2)

  • No

Flame retardant

  • In accordance with EN 60332-1-2 and EN 50399

Low smoke (acc. BS EN 61034-2)

  • No

Outer diameter

  • Approx. 5.2 mm

Operating Temperature Range

  • -20 to 60 °C

NVP value

  • 70 %

Conductor category

  • Class 1 = solid

Total number of cores

  • 8

Stranding element

  • Pairs

Conductor surface

  • Bare

Dielectric strength

  • 1200 V dc or 850 V ac

Maximum Pulling Load

  • 60N/6.1KgF

MBR during installation

  • 8x cable OD

MBR installed

  • 4x cable OD

ISO/IEC 11801-1:2017

  • Information technology – Generic cabling for customer premises: Part 1 General Requirements

IEC 61156-5:2009+AMD1:2012

  • CSV Multicore and symmetrical pair/quad cables for digital communications – Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz – Horizontal floor wiring – Sectional specification

EN 50173-1:2011

  • Information technology. Generic cabling systems – General requirements

EN 50173-2:2007 + A1:2010

  • Information technology. Generic cabling systems – Office premises

BS EN 50288-3-1:2013

  • Multi-element metallic cables used in analogue and digital communication and controlSectional specification for unscreened cables characterised up to 100 MHz. Horizontal and building backbone cables

EN 50399:2011+A1:2016

  • Common test methods for cables under fire conditions. Heat release and smoke production measurement on cables during flame spread test. Test apparatus, procedures, results

IEC 60332-1-2:2004

  • Tests on electric and optical fibre cables under fire conditions.
  • Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kW pre-mixed flame

ANSI/TIA 568-2.D

  • Balanced Twisted-Pair Telecommunications Cabling and Components Standards

IEC 60754-2:2011

  • Test on gases evolved during combustion of materials from cables – Part 2: Determination of acidity (by pH measurement) and conductivity

IEC 61034-2:2005+A1:2013

  • Measurement of smoke density of cables burning under defined conditions – Part 2: Test procedure and requirements

EN 50575:2014 + A1:2016

  • Power, control and communication cables — Cables for general applications in construction works subject to reaction to fire requirements

RoHS

  • Restriction of Hazardous Substances – Compliant

Share your thoughts!

Let us know what you think...

What others are saying

There are no contributions yet.

×

Login

Continue as a Guest

Go to Top