CAT5 Solid U/UTP Outdoor Ethernet Cable Custom Lengths Made to Order
CAT5e Solid U/UTP Outdoor Ethernet Cable is manufactured and tested to the ISO 11801, EN 50173 and ANSI/TIA-568-C standards for enhanced performance Category 5 cables. The cable consists of 8 colour coded polyethylene insulated conductors, twisted together to form 4 pairs with varying lay lengths. These pairs are jacketed in a heat and UV, moisture resistant black polyethylene outer sheath, making this cable ideal for outdoor installation. The print legend on the cable includes information regarding the DOP number, Test and Classification of the cable for traceability.
Key Features
- Category: 5E
- Length: Custom Lengths Made to Order
- Outer sheath colour: Black
- Supports Gigabit Ethernet
- Sequential metre markings
- Reaction-to-fire class according to EN 13501-6: Fca
- AWG-size: 24
- Euroclass Fca
Additional information
Dimensions | N/A |
---|---|
Length | 0.2M, 0.5M, 1M, 2M, 3M, 4M, 5M, 10M, 15M, 20M, 25M, 30M, 35M, 40M, 45M, 50M, 60M, 70M, 80M, 90M, 100M |
Tech Specs
Category
- 5E
Overall screening
- None
Conductor screening
- None
Outer sheath colour
- Black
Reaction-to-fire class according to EN 13501-6
- Fca
AWG-size
- 24
Specification core insulation
- PE
Core identification
- Colour
Outer sheath material
- PE
Halogen free (acc. EN 60754-1/2)
- No
Flame retardant
- In accordance with EN 60332-1-2 and EN 50399
Low smoke (acc. BS EN 61034-2)
- No
Outer diameter
- Approx. 5.2 mm
Operating Temperature Range
- -20 to 60 °C
NVP value
- 70 %
Conductor category
- Class 1 = solid
Total number of cores
- 8
Stranding element
- Pairs
Conductor surface
- Bare
Dielectric strength
- 1200 V dc or 850 V ac
Maximum Pulling Load
- 60N/6.1KgF
MBR during installation
- 8x cable OD
MBR installed
- 4x cable OD
ISO/IEC 11801-1:2017
- Information technology – Generic cabling for customer premises: Part 1 General Requirements
IEC 61156-5:2009+AMD1:2012
- CSV Multicore and symmetrical pair/quad cables for digital communications – Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz – Horizontal floor wiring – Sectional specification
EN 50173-1:2011
- Information technology. Generic cabling systems – General requirements
EN 50173-2:2007 + A1:2010
- Information technology. Generic cabling systems – Office premises
BS EN 50288-3-1:2013
- Multi-element metallic cables used in analogue and digital communication and controlSectional specification for unscreened cables characterised up to 100 MHz. Horizontal and building backbone cables
EN 50399:2011+A1:2016
- Common test methods for cables under fire conditions. Heat release and smoke production measurement on cables during flame spread test. Test apparatus, procedures, results
IEC 60332-1-2:2004
- Tests on electric and optical fibre cables under fire conditions.
- Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kW pre-mixed flame
ANSI/TIA 568-2.D
- Balanced Twisted-Pair Telecommunications Cabling and Components Standards
IEC 60754-2:2011
- Test on gases evolved during combustion of materials from cables – Part 2: Determination of acidity (by pH measurement) and conductivity
IEC 61034-2:2005+A1:2013
- Measurement of smoke density of cables burning under defined conditions – Part 2: Test procedure and requirements
EN 50575:2014 + A1:2016
- Power, control and communication cables — Cables for general applications in construction works subject to reaction to fire requirements
RoHS
- Restriction of Hazardous Substances – Compliant